Hazard Analysis and Risk Assessment

Status: first draft for curation by the safety lead. Machine-generated from the authoritative backbone docs/safety/system_definition.md and the design records under docs/. Every vehicle-level number is an explicit assumption (§2) the integrator must confirm — no severity, exposure, or demand-rate figure has been silently chosen. Function IDs (SF-1..SF-3, F-R-xx, F-H-xx, F-M-xx, F-P-xx) are used verbatim from the System Definition.

Standard frame: IEC 61508 (SIL / systematic capability) for the electronic stop function and ISO 13849 (Performance Level) for the actuation/machinery side. Design target under evaluation: SIL 3 / PL e for the on-demand stop. This document derives the required level from risk parameters and then states whether that target is justified, higher, or lower (§6).

Analysis basis (code, not stale design): per the reconciliation block in SYSTEM_DEFINITION §, the implemented stuck-at / systematic controls are Option A (fresh both-phase physical sample every tick) and Option B (two cores form the verdict by diverse expressions — arithmetic-image vs boolean). Option C (LFSR/PRNG challenge, liveness-XOR accumulator, stamp echo-signature) was dropped 2026-07 and is analysed here as a residual, not a control. integrity_chain_safety_design.md §5–§7 still describe Option C as the target architecture and are stale on that point (see §7 Doc-vs-code register).


1. Scope & method​

This HARA covers the protective-stop (pstop) function as bounded by SYSTEM_DEFINITION §1: a wireless-linked handheld/fixed remote (ESP32-S3, dual-core lockstep, DPST normally-closed stop button on two loops) driving a machine controller (host software runner host/, ROS 2 node ros2/protective_stop_machine/, or ESP32 machn unit) to a de-energized STOP safe state over a Tailscale/WireGuard black channel. The pre-qualified protocol library pstop_c is referenced at its interface (F-P-01..04) and is not re-assessed; only its assumptions-of-use are carried as integration requirements. Hazards are expressed as failures of the pstop function (SF-1..SF-3 violated), following IEC 61508-1 clause 7.4. Risk is rated twice — with the IEC 61508-5 Annex D risk graph (C/F/P/W → SIL) and the ISO 13849-1 Annex A risk graph (S/F/P → PLr) — and the higher demand is carried. The safe state throughout is de-energize-to-safe: absence of a valid, fresh, agreed OK message ⇒ machine heartbeat-times-out ⇒ STOP.

Classification note. The pstop is a protective stop (a normal safeguarding function), not the machine's emergency-stop (E-stop) function under IEC 60204-1 / ISO 13850. The "E-stop switch" is only the hardware part name of the DPST button. The vehicle still requires its own compliant emergency-stop; this HARA does not discharge that obligation.


2. Assumption register (vehicle-level — integrator to confirm)​

These parameters are not derivable from the pstop firmware/design and drive every risk rating below. Each must be confirmed by the vehicle integrator's system HARA before any SIL/PL claim is final.

IDAssumption (worst-case default used here)RationaleConfirmed by
A-01Worst-case consequence of a pstop failure is contact between a moving mobile machine and a person → death or irreversible injury (IEC C2+, ISO S2).Off-highway / industrial mobile vehicle (SYSTEM_DEFINITION §2) has kinetic energy sufficient to crush.Integrator (mass, speed, kinetic energy, guarding)
A-02Operator / bystander exposure to the hazard zone is frequent-to-continuous (IEC F2, ISO F2).Autonomous vehicle operating in shared/occupied space; a remote implies humans nearby.Integrator (site, traffic, exclusion zones)
A-03Possibility of avoiding the hazard is scarcely possible / almost impossible (IEC P2, ISO P2).Autonomous motion, limited human perception of intent, potential blind approach. May reduce to P1 with low speed + audible/visual warning + clear sightlines.Integrator (speed, warning devices, sightlines)
A-04Demand rate on the stop function is unknown; assumed W2–W3 (moderate-to-high).Cannot be inferred from firmware. This single parameter moves the IEC result by up to two SIL steps.Integrator (operational demand analysis)
A-05Process Safety Time (PST) is a vehicle-level number and is unknown. Placeholder PST_min. The pstop's own worst-case signal-latency budget is ≈ 2.1 s on the silence/link-loss path (heartbeat timeout heartbeat_ms × max_missed = 400 ms × 5 ≈ 2.0 s + one 100 ms tick). max_missed is a tunable, raised 3 → 5 on 2026-08-04 to eliminate control-plane-re-sync nuisance stops; this lengthened the budget from ≈ 1.3 s to ≈ 2.1 s.FTTI must satisfy pstop latency + actuation/braking time ≤ PST.Integrator (must confirm PST ≥ 2.1 s + braking; any vehicle previously sized for the 1.3 s budget must be re-checked — else tighten heartbeat_ms/max_missed, at the cost of nuisance-stop margin)
A-06De-energize = STOP is genuinely safe for this vehicle (no rollaway on grade, no hazardous load release, no loss of steering/brake authority when de-energized).The entire architecture rests on de-energize-to-safe (SYSTEM_DEFINITION §5). A vehicle that rolls when de-energized breaks this and needs a held/spring-applied brake.Integrator (grade, brake type, load dynamics)
A-07The final actuation element is either the in-scope ESP32 machn dual relay in series + feedback (MACHINE_ESP32_DESIGN), or an integrator-supplied element of ≥ the allocated PL/SIL. The host/ROS 2 software machine emits a non-safety signal only (MACHINE_ROS2_NODE_DESIGN §1).The safety function is only as good as its final element; the software machine has none in scope.Integrator (actuator selection & rating)
A-08The transport (Tailscale/WireGuard/DERP over WiFi/Eth/USB-NCM) is an untrusted black channel per IEC 61508 / IEC 62280 §; all safety detection lives in the endpoints (CRC-16, counter/stamp echo, heartbeat).The design explicitly treats pstop_c as a black-channel protocol (PSTOP_SAFETY_DESIGN §3).Assessor (residual bit-error / insertion / masquerade rate argued in FMEDA)
A-09pstop_c is a validated SEooC with systematic capability ≥ the allocated target, and its interface obligations F-P-01..04 are met by the shell.SYSTEM_DEFINITION §1 declares it pre-qualified and out of scope.Assessor (SEooC assumptions-of-use vs this integration)
A-10As-configured timing on the safety-credited machine (machn, A-07) is 10 Hz tick, heartbeat_ms = 400, max_missed = 5 (raised from 3 on 2026-08-04), min_stop_ms = 500 and any field reconfiguration stays inside the validated safe envelope max_missed ∈ [1,5] (ROS 2 validator refuses looser values). max_missed = 5 now sits at the envelope ceiling — there is no headroom to loosen it further without widening the validated envelope.SYSTEM_DEFINITION §2; MACHINE_ROS2_NODE_DESIGN §4/§12 (envelope).Integrator (commissioned config)

3. Hazard identification​

Hazards are failures of the pstop function. Cause classes: RHW = random hardware; SW = systematic software; CCF = common-cause (dual-core / channel); BC = black-channel / comms; H/O = human / operational.

Hazard IDHazardous event (pstop function failing)Operating situationSF violatedCause classes
H-01Fail-to-stop on demand — button pressed or a fault is present, yet the machine holds a RUN/OK state.Person enters path; operator presses stop.SF-1RHW (masked stuck sense pin), SW, CCF, BC (forged/held OK)
H-02Spurious / nuisance stop — machine stops with no demand and no fault.Vehicle moving in traffic / carrying load / on grade.(counter-risk to SF-1; secondary hazard)RHW (EMC blip), SW, tight max_missed margin
H-03Delayed stop beyond PST — stop is commanded but arrives after the process safety time.High-speed approach; short PST.SF-1 (timeliness)BC (DERP dark window 5–9 s; degraded-mode ladder), heartbeat timeout, debounce
H-04False / spontaneous arming — machine transitions STOP→OK without a deliberate operator gesture.Unattended vehicle re-energizes itself.SF-3RHW (EMC both-channel blip), CCF, BC (replayed OK), H/O
H-05Undetected loss of remote link — remote is gone/silent but the machine keeps believing a stale OK.Link drops mid-operation.SF-2BC, SW (frozen get_time_cb — F-P-03 breach), RHW
H-06Stale / replayed OK accepted — an old valid OK is replayed or held and treated as fresh.Adversarial or fault-induced packet replay.SF-2BC, SW
H-07One-of-many-remotes masking — in many→one, a misbehaving/ghost remote's OK or a lost bond masks another remote's STOP, or arming ownership is confused.Multiple bonded remotes on one machine.SF-1 / SF-3SW, BC, H/O
H-08Boot-time transient OK — power-on loop glitch puts a STOP→OK episode on the wire, self-arming the machine.Every remote power-up / OTA reboot.SF-3RHW (boot GPIO transient), SW
H-09Common-cause dual-core systematic SW fault — an identical bug on both cores yields identical wrong OK; the byte comparator agrees.Any; latent until triggered.SF-1 / SF-2CCF, SW
H-10Machine-side relay weld / stuck-on — the final element cannot de-energize; commanded STOP does not open the stop circuit.Contact welds after many cycles / driver short.SF-1RHW
H-11Forged / fail-danger OK on the black channel — partial corruption or the all-zeros/OK==0x00 polarity produces an OK the machine accepts.Bit errors, buffer zeroing, malicious injection.SF-1 / SF-2BC, RHW
H-12Final actuation element not safety-rated — software/ROS 2 machine's STOP is a non-safety signal the robot control stack may ignore or delay.Software or hardware-proxy machine deployment.SF-1(architectural / scope)
H-13Non-operator remote re-arms the machine — an accepted-but-not-authorized (stop-only) remote, or any remote absent from the machine's operator allowlist, performs a STOP→OK re-arm and resumes the machine.Machine STOPPED; a remote that was admitted only to stop drives (or completes) the arming gesture.SF-3SW, H/O (mis-configured operator allowlist)

4. Risk assessment​

Ratings use the worst-case assumptions of §2 (A-01 severity, A-02 exposure, A-03 avoidance, A-04 demand). The result is therefore an upper-bound envelope; the integrator's confirmed parameters may lower it.

IEC 61508-5 Annex D key: C = consequence (C1 minor … C2 death of one … C3/C4 multiple); F = exposure (F1 rare … F2 frequent/continuous); P = avoidance (P1 possible … P2 almost impossible); W = demand rate (W1 low … W3 high). ISO 13849-1 Annex A key: S = severity (S1 slight/reversible, S2 serious/irreversible); F = exposure (F1 seldom, F2 frequent); P = avoidance (P1 possible, P2 scarcely possible).

HazardCFPW→ SILSFP→ PLrReasoning
H-01C2+F2P2W2–W3SIL 3S2F2P2eThe defining demand of the function. Person in path + unavoidable + frequent exposure → ISO lands squarely at PLr e (S2·F2·P2). IEC gives SIL 2 at W2, SIL 3 at W3; carry SIL 3 as the conservative envelope for unattended autonomy. Chief risk driver.
H-02C2F2P1W1–W2SIL 1–2S2F2P1c–dA nuisance stop is not itself the primary hazard, but a sudden de-energize in traffic / on grade / under load (A-06) can cause secondary collision or load shift → not negligible. Avoidance is easier (P1: predictable stop). Managed by fail-safe-direction-only debounce; never rated above the primary function.
H-03C2+F2P2W2–W3SIL 3S2F2P2eSame outcome as H-01 for the collision — a stop after PST is a fail-to-stop. Amplified by the measured 5–9 s DERP failover dark window and the degraded-mode ladder pausing Tailscale. Timeliness is a first-class safety property here, not just availability.
H-04C2+F2P2W2SIL 3S2F2P2eSpontaneous re-energize of an unattended machine puts a person at risk with no human in the loop. The EMC both-channel-blip self-arming failure is documented as having occurred (FAILOVER_AND_ARMING §2), so likelihood is credible, not theoretical.
H-05C2+F2P2W2SIL 3S2F2P2eUndetected staleness defeats the whole freshness premise (SF-2). Heartbeat on the machine's own monotonic clock is the control; a frozen get_time_cb (F-P-03 breach) is the dangerous-undetected residual.
H-06C2+F2P2W2SIL 3S2F2P2eAnti-replay now rests solely on pstop_c native counter monotonicity + MSG_LOST/OUT_OF_ORDER bounded-loss (F-P-04). The extra stamp echo-signature (Option C) was dropped, so the residual is larger than PSTOP_SAFETY_DESIGN §5.3 implies.
H-07C2+F2P2W2SIL 3S2F2P2eFail-safe OR (any STOP or any silence wins) is the primary control (F-H-05); the residual is a ghost bond that still counts as present-and-OK, and arming-ownership confusion. Validated 32/32 in pstop_multi_remote_test.py but unquantified for random-fault masking.
H-08C2+F1P2W1SIL 2S2F1P2dExposure is per-boot (F1), not continuous, so lower W/F — but a boot that self-arms is severe. Boot warm-up hold (LOOP_BOOT_OPEN_CONFIRM_TICKS = 5) is the control; residual only if the hold is insufficient on some board.
H-09C2+F2P2W2–W3SIL 3S2F2P2eThe dominant systematic risk (PSTOP_SAFETY_DESIGN G1, β≈1 for a shared bug through a byte comparator). Only lever implemented is Option B diverse expressions; the "semantic 1oo2D" comparator (§5.4) was not built. Diversity sufficiency is unquantified — no FMEDA.
H-10C2+F2P2W2SIL 3S2F2P2eClassic dangerous-undetected. ESP32 machn: two relays in series (either breaks) + feedback contradiction → stop-on-contradiction ≥ ~1 s gives HFT=1 + diagnosis. Residual: a single-channel or software machine has no in-scope rated relay (A-07, H-12). [DESCOPED 2026-08 — the feedback/diagnosis half is OFF by default pending new machine HW, REVERSIBLE (CONFIG_MACHN_RELAY_FEEDBACK); see docs/design/relay_feedback_descope.md. HFT=1 from the series relays is UNCHANGED (stop-on-demand safe), but the stuck-on diagnosis + stop-on-contradiction are removed, so a single weld is latent-to-next-demand. Compensate with a periodic commanded-open proof test.]
H-11C2+F2P2W2SIL 3S2F2P2eOK==0x00 is an inherited fail-danger polarity (all-zeros decodes toward OK, SYSTEM_DEFINITION §5). Compensated by CRC-16 over bytes[0..37] (a zeroed CRC won't match), transmit-on-agreement, and the live-sample derivation. Standing FMEA anchor.
H-12C2+F2P2W2SIL 3S2F2P2eFor the software/ROS 2 machine the "STOP" is a ROS topic explicitly carrying no safety responsibility; enforcement reduces to remotes fail-safe-stopping on their own heartbeat timeout. The final element integrity is unallocated unless the integrator supplies it. Architectural gap, not a coding defect.
H-13C2+F2P2W2SIL 3S2F2P2eSame collision outcome as H-04: an unattended machine re-energized by a remote never authorized to resume it (only to stop it). The control is pstop_c gating the STOP→OK ownership on is_stop_only == false (machine.c:135-142); a stop-only remote's STOP still forces STOP (:131,155-156) and it is heartbeat-monitored (machine_check_heartbeats:266-320). The default is maximally safe — the operator allowlist is empty out of the box, so every bonded remote is stop-only until explicitly promoted. Residual is a mis-configured allowlist that mints a non-operator as operator (FMEA H02-4).

5. Safety goals​

Positive requirements that, if met to the allocated integrity, close the hazards. FTTI / PST entries reference the A-05 placeholder because the absolute number is a vehicle-level input.

SGSafety goal (positive requirement)Safe stateFTTI / PSTAllocated targetCloses
SG-1On any stop demand or any detected fault, command the machine to de-energized STOP within the fault-tolerant time.De-energized (no valid OK)≤ PST_min (A-05); pstop budget ≈ 2.1 s worst case (max_missed = 5 since 2026-08-04)SIL 3 / PL eH-01, H-03, H-09, H-11
SG-2Sustain OK only while it is freshly and causally derived from a live both-channel read and a valid black-channel round-trip; stale/replayed/forged OK must fail to STOP.De-energized on any staleness≤ heartbeat timeout ≈ 2.0 sSIL 3 / PL eH-05, H-06, H-11
SG-3Permit STOP→OK only via a deliberate arming gesture (STOP held ≥ min_stop_ms = 500 ms, then release) and only from a remote on the machine's operator allowlist (is_stop_only == false, default empty); never spontaneously, on a transient, at boot, or from a stop-only / non-operator remote.Remain STOPPED until a valid gesture from an authorized operatorn/a (state guard)SIL 3 / PL eH-04, H-08, H-13
SG-4In many→one, any bonded remote's STOP or silence forces STOP regardless of other remotes (fail-safe OR); arming requires a single owning gesture, and a lost/ghost bond must not read as present-and-OK.De-energized if any remote demands/absent≤ heartbeat timeoutSIL 3 / PL eH-07
SG-5The final actuation element shall de-energize-to-safe with HFT = 1 and diagnosable stuck-on (relay-output feedback), or the integrator shall provide an element of ≥ the allocated integrity. Software/ROS 2 machine outputs are non-safety and must not be the sole enforcement path. [DESCOPED 2026-08: the "diagnosable stuck-on (relay-output feedback)" limb is OFF by default on machn pending new machine HW, REVERSIBLE (CONFIG_MACHN_RELAY_FEEDBACK) — docs/design/relay_feedback_descope.md. The HFT=1 de-energize-to-safe limb still holds; the requirement now rests on the integrator-supplied element OR restoration of feedback on the new HW. Stuck-on diagnosis is a documented gap meanwhile.]Stop circuit open≤ RELAY_FEEDBACK_MS + ~1 s contradiction holdSIL 3 / PL e (allocated to integrator for software machine)H-10, H-12
SG-6Bound the spurious-STOP rate so it does not introduce a secondary hazard (traffic/grade/load), without ever filtering or delaying the stop path (asymmetric, fail-safe-direction-only debounce).STOP is always permitted; only re-arm is gatedopen→STOP single-tick (~100 ms)No de-energize SIL (availability goal, fail-safe by construction); manage per A-06H-02

6. Integrity-target conclusion — is SIL 3 / PL e correct?​

ISO 13849 (PLr): confirmed at PL e. Under the worst-case assumptions the severity/exposure/avoidance triple for the primary hazards (H-01/03/04/05/06/07/ 09/10/11/12/13) is S2 · F2 · P2, which lands directly on PLr = e with no ambiguity. PL e is the correct machinery-side requirement for an unattended mobile autonomous vehicle whose pstop failure can kill an unavoidable bystander. It is not higher (there is no PL above e); it drops to PL d only if the integrator confirms P1 (avoidable — low speed, warnings, sightlines) or F1 (rare exposure), which A-02/A-03 do not currently support.

IEC 61508 (SIL): SIL 3 is the correct conservative target, but it is demand-rate-sensitive. The risk graph gives SIL 2 at W2 and SIL 3 at W3 for the C2·F2·P2 hazards. Because the demand rate W is unknown (A-04) and the vehicle is unattended, SIL 3 is the right design envelope and is consistent with the ISO PL e result (ISO 13849-1 Table 4 maps PL e ↔ SIL 3). If the integrator's demand analysis firmly establishes low demand (W1–W2) and avoidability (P1), a SIL 2 allocation could be justified for the electronic function — but that is a deliberate downgrade the safety lead must sign, not a default.

Architecture supports the SIL 3 claim only conditionally. The design provides the structural preconditions:

  • HFT = 1, remote 1oo2D to stop / 2oo2 to run, machine relay de-energize-to-safe (SYSTEM_DEFINITION §2; PSTOP_SAFETY_DESIGN §9).
  • ESP32 machn final element is 1oo2D in series with output feedback → HFT = 1 on actuation with stuck-on diagnosis (MACHINE_ESP32_DESIGN).
  • Continuous per-tick online proof test (Option A both-phase), fail-safe default STOP, asymmetric debounce, arming policy, boot warm-up hold.

However, the quantitative SIL 3 claim is not yet supported, and three items gate it:

  1. No FMEDA. SFF, DC, PFH/PFD_avg, and β are unquantified. SIL 3 route 1H demands (per IEC 61508-2) SFF ≥ 99 % at HFT 1, PFH 10⁻⁸–10⁻⁷/h. None is demonstrated. This is a hard blocker on the numerical claim.
  2. Common-cause coverage rests on Option B diversity through a byte comparator. The design's own G1 says a byte-identical memcmp gives ≈0 systematic coverage; the "semantic 1oo2D" comparator that was meant to fix this (§5.4 / D1) was not implemented. The SIL 3 systematic case therefore hangs entirely on Option B's arithmetic-image-vs-boolean diversity being sufficient to diverge the two byte streams under a shared bug — credible but unproven (fault-injection row 9 of PSTOP_SAFETY_DESIGN §10 must pass).
  3. Systematic capability (SC 3). SIL 3 requires SC 3 process rigour on the new sensing/comparator/arming code. MISRA C is done (misra_c_compliance_review.md); static analysis in CI, requirements traceability, and structured fault-injection are claimed but not yet evidenced to the SC 3 bar (the coverage regime in SYSTEM_DEFINITION targets it).

Verdict: SIL 3 / PL e is the correct target and the architecture is plausibly capable of it, but the claim is currently unsubstantiated. Treat SIL 3 / PL e as allocated, not achieved, pending FMEDA + fault-injection evidence + integrator confirmation of A-01..A-05.


7. Open items — inputs the integrator / vehicle HARA must supply​

Vehicle-level inputs (block the risk ratings):

  1. Confirm or replace A-01..A-05: worst-case severity, exposure, avoidability, demand rate W, and Process Safety Time. W and PST are the two numbers that can move the SIL result and the FTTI budget.
  2. Confirm A-06: that de-energize is truly safe (no rollaway on grade, no hazardous stored energy). If not, add a spring-applied / held brake and re-rate — de-energize-to-safe is otherwise invalid.
  3. Confirm A-07/SG-5: who owns the final actuation element for the software/ROS 2 machine. As drawn, that machine has no rated final element in scope (H-12) — enforcement is only the remotes' fail-safe timeout.

Evidence blocking the SIL 3 / PL e claim:

  1. FMEDA for the remote sensing chain and the machine relay chain: SFF, DC, β, PFH. Without it there is no quantitative SIL/PL claim (§6.1).
  2. Fault-injection proof of Option B diversity (PSTOP_SAFETY_DESIGN §10 row 9): inject an identical logic fault into both cores' sensing and show the byte encodings still diverge. If they do not, common-cause (H-09) is uncontrolled and SIL 3 fails.
  3. Anti-replay residual (H-06): argue the pstop_c native counter / MSG_LOST bounded-loss window is sufficient without the dropped stamp signature, quantified against A-08.
  4. Frozen-clock diagnostic (H-05): demonstrate the machine's get_time_cb cannot silently stall (F-P-03), or add a monotonicity check.
  5. DERP dark-window vs PST (H-03): the measured 5–9 s failover gap and the degraded-mode ladder must be shown ≤ PST, or STOP must be forced during the gap. This is likely to fail for any short-PST vehicle and needs explicit treatment. Note (2026-08-04): the silent-remote detection latency itself was lengthened from ≈ 1.2 s to ≈ 2.0 s (max_missed 3 → 5), which further tightens the H-03 PST margin for short-PST vehicles even on the non-failover path — re-check A-05 against the vehicle PST.
  6. Confirm the pstop is not credited as the machine's emergency-stop; verify an independent IEC 60204-1 / ISO 13850 E-stop exists.

Doc-vs-code register (found during this analysis — fix before sign-off):

#LocationInconsistency
D1PSTOP_SAFETY_DESIGN §5.6 vs SYSTEM_DEFINITION §2 (+ MACHINE_ROS2 §12, memory)Heartbeat timeout formula and values are stale: design doc says heartbeat_ms × (max_missed + 1), "1000 × 2 ≈ 1–2 s"; the code/backbone is heartbeat_ms × max_missed, 400 × 5 ≈ 2.0 s (max_missed raised 3 → 5 on 2026-08-04; was 400 × 3 ≈ 1.2 s).
D2PSTOP_SAFETY_DESIGN (whole doc) vs SYSTEM_DEFINITIONDesign doc is SIL 2-framed throughout; the backbone target is SIL 3 / PL e.
D3PSTOP_SAFETY_DESIGN §5, §6 (fault→reaction map), §7 vs SYSTEM_DEFINITION reconciliation§5–§7 describe Option C (LFSR challenge Cn, liveness accumulator S ^= (Cn^En), stamp echo-signature) as the implemented target architecture. Option C was dropped 2026-07. The actual stuck-at/systematic controls are Option A (both-phase fresh sample) + Option B (diverse expressions). The §6 fault→reaction map cites mechanisms that do not exist in the code.
D4PSTOP_SAFETY_DESIGN §4 gap G3Lists predictable counter&1 as an open gap "lowering DC". Moot/misleading: Option A both-phase is the adopted compensating measure, not the dropped LFSR.
D5PSTOP_SAFETY_DESIGN §5.4 / §8 D1 vs SYSTEM_DEFINITION F-R-04Recommends a semantic 1oo2D comparator; the implemented comparator is still byte-identical memcmp of the 40-byte encodings. Common-cause coverage therefore depends on Option B diversity, not the semantic comparator the doc credits.
D6MACHINE_ROS2_NODE_DESIGN §1 vs whole-system expectationFor the software machine the STOP output is explicitly non-safety; the final-element integrity for that form factor is undefined in scope (H-12). Not a contradiction, but a scope gap the safety case must close.

End of draft. Every SIL/PL figure above is conditional on §2 and the §7 evidence. Curate against the vehicle HARA before any external safety claim.