Date: 2026-07-22.

[Reconciled 2026-08-02] The heartbeat-timeout formula below is corrected to the library math heartbeat_ms × max_missed_heartbeats (machine.c:290-298); it previously read × (max_missed_heartbeats + 1). Full register: docs/safety/documentation_and_code_reconciliation.md (R-07).

Validates the pstop_c machine logic when multiple remotes heartbeat one machine, across the corner cases a fleet actually hits. Two-part (hybrid): exhaustive software remotes for coverage, plus the two real chips end-to-end over the real transport.

The logic under test (pstop_c, unmodified)​

machine.c implements a fail-safe OR: the robot runs (OK) only while every bonded remote is OK and no arming cycle is pending. Any of the following drives STOP:

  • a remote sends STOP,
  • a remote goes silent past heartbeat_ms x max_missed_heartbeats (machine.c:290-298),
  • a remote unbonds (disconnect),
  • a remote sends a malformed / bad-CRC / invalid-type message (rejected; its heartbeat is not fed, so it times out to STOP),
  • the machine reaches capacity and rejects a new remote.

Arming ownership: the first non-stop_only remote to STOP owns the STOP->OK re-arm cycle (remote_stop_id). A different remote can STOP the robot but cannot itself re-arm — the owner must, or the owner must unbond/time-out first (which releases ownership). Fail-safe: it is only ever harder to arm. stop_only operators may STOP but never arm.

Safety invariants asserted (all held)​

#Invariant
I1any bonded remote sending STOP -> every remote sees STOP
I2a remote silent > timeout -> robot STOP
I3robot never OK without a deliberate held STOP->OK cycle
I4a STOP shorter than min_stop_ms (500 ms) cannot arm
I5a freshly (re)bonded remote forces re-arm (NEED_STOP)
I6the (max_remotes+1)th remote is rejected; armed peers undisturbed
I7unbonding the arming owner drops the robot to STOP/NEED_STOP

Part 1 — software-remote corner-case matrix (32/32 PASS)​

tools/pstop_multi_remote_test.py — spins up host/machine_app_runner (linking the unmodified library) and drives it with N scripted remotes that speak the real 40-byte wire protocol (CRC16 0x8D95), each with its own device_id + counter handshake. Groups:

  • A single-remote arming policy (arm / veto / re-arm)
  • B two-remote arming + any-STOP OR + ownership
  • C heartbeat loss (network drop / power-off) + re-arm on reconnect
  • D unbond / disconnect (owner leaves, ownership release, last-remote)
  • E capacity overflow (max_remotes=3), allowlist deny, stop_only
  • F malformed: UNKNOWN, sustained bad-CRC, out-of-range type
  • G network chaos via tools/pstop_chaos_proxy.py (loss/delay/jitter/dup): arm through proxy, heavy loss -> STOP, recovery -> re-arm, churn never spuriously arms.

Run: cd tools && uv run python pstop_multi_remote_test.py (exit 0 = all invariants held).

Part 2 — real two-chip end-to-end​

Both flashed chips against one machine_app_runner on the laptop (machine.toml: max_remotes=3, max_missed=1, min_stop_ms=500, allow_unlisted):

  • pstop-01d778b4 (0x01D778B4) — new chip, USB-NCM tether (10.42.0.1:8890)
  • pstop-01d7791c (0x01D7791C) — old chip, Tailscale (100.110.35.58:8890)

Observed on the machine:

P1 near-simultaneous OK  -> ANOMALY: arming VETOED from 0x01D778B4 (100ms < 500ms)   [I4]
P2 NEW held STOP 1200ms -> OK -> ARMED by 0x01D778B4; Robot Status = OK
P3 OLD STOP while armed -> Robot Status = STOP [I1]
P6 both released to STOP -> disarmed; both chips pstop_last_msg=1 (STOP) fail-safe

Confirms bond, arm, and the any-STOP OR work end-to-end with real hardware over both transports.

Test-only software E-stop stub (added, used, REMOVED)​

The remotes have no physical E-stop switch wired, so they always read STOP and cannot exercise the OK/arming path. A gated software override was added ONLY for this test:

  • CONFIG_DCS_ESTOP_SW_STUB (Kconfig, default n), forcing a build #warning.
  • POST /api/estop_stub?state=ok|stop|clear overriding compute_verdict() (fail-safe default = passthrough to the real hardware read).
  • Every piece tagged TODO(SAFETY): REMOVE before certification.

Safety compliance: a protective-stop verdict must derive ONLY from the dual-channel hardware loop. The stub deliberately bypasses that cross-check, so it was fully reverted after testing — the code is gone from the tree (git clean), both chips were restored to clean b19a754, and the /api/estop_stub endpoint now 404s on both. It was never committed or shipped.

To reproduce the stub for future bench work, re-add the gated option (never enable it in a production/certified build) — see git history of this doc's session, or the pattern above.

Findings​

No unsafe behavior. All STOP/timeout/reject paths are fail-safe. Observations (all safe-by-design):

  • Arming ownership sticks to the first arming remote until it unbonds or times out; a second remote can STOP but not re-arm. Intended, fail-safe.
  • UNKNOWN and out-of-range message types are rejected (not fed to the heartbeat) -> STOP arrives via timeout, not instantly. Same effect as silence.
  • httpd user-handler budget (dcs_support.c max_user_uri_handlers=16) was at its limit; adding one more handler (the stub) silently failed to register until bumped. Worth watching if more /api routes are ever added in prod. [Reconciled 2026-08-07] Raised to max_user_uri_handlers=30 (46 total slots for microlink's ~20 + dcs's 21); comment in dcs_support.c documents the arithmetic to re-check on any new route. No longer at the limit.